> For the complete documentation index, see [llms.txt](https://evalan.gitbook.io/wattmaestro/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://evalan.gitbook.io/wattmaestro/documentation/installation-guidelines.md). Agents can also search and read this documentation through its [MCP server](https://evalan.gitbook.io/wattmaestro/~gitbook/mcp).

# Installation Guidelines

The following document aims to describe generically how to connect Wattmaestro Gateway with a piece of Equipment.

## Introduction

To benefit from Wattmaestro services, the Site Installation, i.e. any steps to enable the communication and the control of the Equipment(s) with Wattmaestro (BACE) Gateway, is an important phase.

Every installation will depend on the piece of Equipment communication requirements, that can be retrieved on the [SetUp Wizard](https://dashboard.bace-iot.com/wizard). Further below are described some generic recommendations on how to onboard a Wattmaestro Site.

## Gateway Placement

For durability and stability purposes, where to place the Wattmaestro Gateway is primordial. Are described below a list of generic advices that can help placing the Gateway in the Site.

A 220V electrical power outlet must be available to power the Gateway.

### Signal Strength

Wattmaestro Gateway can connect to the Internet through different ways:

* Cellular connection (4G): primary and recommended way for a Gateway to connect
* Ethernet: use the UTP cable (provided) to connect the Gateway to a Router, the Gateway will automatically connect to Internet via Ethernet. If the Ethernet Port of the Wattmaestro Gateway is already used for Modbus TCP/IP, an Ethernet Switch can be used
* WiFi: contact your Evalan representative to connect your Wattmaestro Gateway with WiFi

To ensure a steady connection, and depending on the way to reach Internet, the following advices apply:

* **Avoid "Faraday Cages"**: Never place a gateway inside a solid metal electrical cabinet if it relies on wireless signals. The metal will block the radio waves.&#x20;
* **Increase Height**: The higher a Gateway is placed, the more chance a steady connection there will be&#x20;

### Environmental Protection

* **Humidity and Moisture Protection**: For durability purposes, it is recommended to place your Wattmaestro Gateway inside an IP65 (or higher rating) cabinet
* **Temperature control**: Ensure there is adequate airflow. In small enclosures, heat can build up and damage the Gateway in the long term.

### Distance Interference

* **Stay Away from "Noise"**: Keep the gateway at least 1 meter (3 feet) away from high-voltage cables, large transformers, or heavy-duty motors. These generate electromagnetic interference (EMI) that can corrupt data packets.
* **Cable Length Limits**: If you are using RS485 (Modbus), you have more distance flexibility (up to 1,200m), but if you are using Ethernet, keep the run under 100m without a switch.

## Enable Communication

The following recommendations aim to described generically how to enable communication between the Wattmaestro Gateway and the Equipment(s).

### Communication Port

Finding the Communication Port of the Equipment is a primordial first step. This information is often disclosed in the manufacturer booklet. For Inverter, the communication port is often placed at the lower part of the Equipment, as presented below.

<figure><img src="https://650603460-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVQbOKHZXDnJ7jFHnFnC%2Fuploads%2FNeIA0ErdHEBnxZCdV5nx%2Fimage.png?alt=media&amp;token=19e8a439-e5f1-4cbb-a179-b47eb764c2b0" alt=""><figcaption></figcaption></figure>

Communication Port placement might differ from one manufacturer to another, refer to the SetUp Wizard dedicated instructions for your Equipment.

### Wiring

When the right Communication Port is identified, connect the Wattmaestro Gateway with the Equipment(s), using the following cable(s) - *provided by Evalan*:

* UTP cable with a RJ45 (Ethernet) port to enable Modbus TCP/IP communication
* UTP cable with a RJ12 port to enable P1 communication\*
* 3-wires cables to enable Modbus RTU communication\*\*

\* A specific version of the Gateway must be ordered to use P1 communication protocol. Contact your Evalan representative for more information

\*\* Most of the Equipment only use A and B pins, and do not require the Ground pin. It is important to note that A and B are sometimes switch in the Equipment set up, if the communication is not yet enabled, you may switch A and B. To identify which A and B pins in the Wattmaestro Gateway, refer to this [document](https://docs.bace-iot.com/reference/wiring-iot-connectivity-modules).

### On-board your Wattmaestro Site

When the Gateway is correctly placed and wired with the Equipment, power on the Gateway and follow the [SetUp Wizard](https://dashboard.bace-iot.com/wizard) instructions to onboard your Site.

First, onboard your piece(s) of Equipment you need to onboard by selecting the Equipment Type (Battery, PV Inverter, EV Charger, etc...) and the Brand/Model.

<figure><img src="https://650603460-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVQbOKHZXDnJ7jFHnFnC%2Fuploads%2FsaVIPVwgEuTB4qsPDTnv%2Fimage.png?alt=media&amp;token=a33da664-9f72-4029-a3bf-a7da57caa328" alt=""><figcaption><p>On-board your Equipment (Battery, Inverter, EV Charger, etc..) one-by-one</p></figcaption></figure>

Then, when **each** of your Equipment are on-boarded, complete the last steps by clicking on Next. Your Equipment you should appeared in the Configured Equipment list (highlighted in green below).

<figure><img src="https://650603460-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FzVQbOKHZXDnJ7jFHnFnC%2Fuploads%2FjxhDXK3TYNTp87xSoyZ7%2Fimage.png?alt=media&amp;token=611ef85a-9ea3-40da-9f5c-f863c0934cba" alt=""><figcaption><p>Complete Site Configuration after on-boarding every Equipment</p></figcaption></figure>

## Assistance <a href="#assistance-1" id="assistance-1"></a>

If you have any questions on the platform, please contact your Evalan representative or send a message at <info@evalan.com>